Architects : Atelier Jean Nouvel

CUstom Engineering

READ MORE

Custom-made studies

Singles points such as angles, seismic and coastal zone construction or deported cladding need custom made studies. Fixinox design office regularly answers to these non standard situations.

Calculations attached.

Référence : Beerse

chantier beerse solution particulière
Problem

The facing precast panel needs to be fixed to concrete beams of unequal height

Solution

The bearing load is supported by one stronger hanger only instead of two. We have developed two custom-made wind and restraint anchors. They are not similar. The dimensioning   target is to stabilize the panel on the facade by facing all horizontal loads and avoid rocking. It takes into consideration the worst load situation.

Wind load restraint anchor

Roof FIXI3D Hanger

Flat fixing dowel for small thickness concrete

Downloads

 

 

Advantages

  • STANDARD ELEMENTS ADAPTATION PRIVILEGED
  • SINGLE POINTS STUDIED
  • CALCULATION SHEETS GIVEN ON REQUEST
  • LAYOUT SHEETS

projects

Precast concrete

 READ MORE

Formulaire de contact

    Name*

    Email*

    Entreprise*

    File

    Subject*

    Message*